- Rated working voltage: 4 to 100V DC
- Nominal capacitance range: 0.1 to 1,500μF
- Capacitance tolerance (120Hz 20 degree Celsius): ±20% (M)
- Leakage current: I≥0.01CRUR or 3 (uA), whichever is greater (after 2 minutes application of rated voltage)
- CR: nominal capacitance (uF)
- UR: rated voltage (V)
- Dissipation factor (120Hz 20 degree Celsius): UR 4, 6.3, 10, 16, 25, 35, 50, 63, and 100V
- Tand: ≤O8, 0.35, 0.26, 0.20, 0.16, 0.14, 0.12, 0.12, 0.12, and 0.10
- Load life: after 2,000 hours application of WV at +85 degree Celsius
- The capacitor shall meet the following limits:
- Capacitance change: ≤ ±20% of initial value (4V: within ±25%)
- Dissipation factor: ≤200% of initial specified value
- Leakage current: ≤ initial specified value
- Shelf life: after storage for 1,000 hours at +85 degree Celsius
- Dissipation factor: not more than the initial specified value
- Leakage current: not more than the initial specified value
- Capacitance change: within ±10% of the initial value
- Operating temperature range: -40 to +85 degree Celsius
|
|
|
|
| Select Image |
 |
|
|
|
|